US: SAE J3067 (J2735 SE) - WAVE WSMP
Description:
This solution is used within Canada and the U.S.. It combines standards associated with US: SAE J3067 (J2735 SE) with those for V-X: WAVE WSMP. The US: SAE J3067 (J2735 SE) standards include a proposed solution for the upper-layers to implement V2X information flows that do not yet have fully standardized messages, functionality or performance characteristics. The V-X: WAVE WSMP standards include lower-layer standards that support connectionless, near constant, ultra-low latency vehicle-to-any communications within ~300m using the WAVE Short Messaging Protocol (WSMP) over IEEE WAVE in the 5.9GHz spectrum. The broadcast mode is interoperable with M5 FNTP.Relevant Regions:
- Canada
- United States
Comm Profile: V-X: WAVE WSMP
Comm Class: LAN - Local Area Network
Standards in Profile:
Level | Standard |
---|---|
Access | Bundle: WAVE - Subnet |
Security | Bundle: IEEE 1609.2 |
TransNet | IEEE 1609.3 WAVE - Networking Services |
Data Profile: US: SAE J3067 (J2735 SE)
Standards in Profile:
Level | Standard |
---|---|
Facilities | SAE J2945/0 DSRC Common Design Elements |
ITS Application Entity | SAE J3067 DSRC Prop Mods to 2735 |
Solution Issues Severity: 30
The severity issue score calculation only includes issues associated with standards that are included by default.
Solution Issues:
Default | Severity | Name | Type | Description |
---|---|---|---|---|
True | Medium | Overlap of standards | Overlap | Multiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow. |
True | Medium | Uncertainty about trust revocation mechanism | Security Gap | The mechanisms used to prevent bad actors from sending authorized messages is unproven. |
True | High | Draft not available (Critical) | Standardization Gap | The standards development organization has established a work item for the subject standard but a draft is not available for this critical feature to enable the interface. The draft may be missing due to the work item being new or simply a lack of activity on the work item. |
True | High | Not a standard (severe) | Standardization Gap | Although the document is publicly available, it has not been the subject of a rigorous industry review and is only provided as informal guidance. It is expected that details will change significantly prior to adoption as a standard. |
True | High | Regulatory Issue | Standardization Gap | Deployment of this standard is subject to regulatory approval, which is not currently expected to be granted for deployments in the near-term. |
Solution to Triples
This solution is used on the following information flow triples: